• Amprobe AM-510 CAL [5160524] Commercial/Residential Digital Multimeter with Voltect NCV Detector and NIST Calibration

Amprobe AM-510 CAL [5160524] Commercial/Residential Digital Multimeter with Voltect NCV Detector and NIST Calibration

Not yet rated Write a review
Amprobe
Rp.4.850.000
Availability:
2 - 4 WEEKS
Product Code:
5160524
Brand:
Amprobe
Update Terakhir:
13 May 2017
This product has a minimum quantity of 3
  • Free delivery

  • Money back guarantee

Share

The Amprobe AM-510 CAL Commercial/Residential Multimeter is designed for light commercial and advanced residential applications. Re-wire electrical panels, install heated floors or new light fixtures, troubleshoot and repair home appliances, electrical sockets and automotive electrical problems with this easy-to-use multimeter. The AM-510 CAL features a built-in flashlight to see wires and fuses in the dark, a rubber tilt stand and probe holder to give you the "third-hand" you need while taking measurements.

The AM510CAL offers safety features including Voltect non-contact voltage detection for quick go/no-go checks without the need for an additional tool. Compact yet tough, this multimeter is built to last through all your electrical projects.

  • NIST Calibration Included
  • Measures AC/DC voltage up to 600V, AC/DC current, resistance, frequency, capacitance, duty cycle and temperature
  • CAT III 600V safety rated
  • Non-contact voltage detection enhances safety
  • Audible continuity quickly identifies shorts and opens
  • Diode test to verify diode polarity
  • Data hold freezes the reading on the display for further analysis
  • MIN/MAX recording records min/max measurements over time to show voltage fluctuations
  • Relative zero mode displays the difference between the actual reading and a stored reference value and may be used with any function or range
  • Offers user friendly features, including auto power-off to conserve battery life, low battery warning, "third hand" test probe holder, built-in test leads storage, a built-in flashlight, and a Velcro strap to hang the meter
  • Auto and manual-ranging delivers maximum flexibility
  • Backlit LCD display makes it easy to view results

  • AC Voltage:
  • Range: 400 mV, 4.000 V, 40.00 V
  • Accuracy:  +/- (1.0 % rdg + 3 LSD)
  • Range: 400.0 V, 600 V
  • Accuracy: @ 45 Hz to 400 Hz, 4 V to 400V ranges
  • DC Voltage:
  • Range: 400 mV, 4.000 V, 40.00 V
  • Accuracy: +/- (0.8% rdg + 1 LSD)
  • Range: 400.0 V, 600 V
  • Accuracy: @ 4 V to 400 V ranges
  • Resistance:
  • Range: 400.0 µA, 4000 µA; 40.00 mA, 400.0 mA; 4.000 A, 10.00 A
  • Accuracy:  +/- (1.2% rdg + 3 LSD)
  • AC Current:
  • Range:  400.0 µA, 4000 µA; 40.00 mA, 400.0 mA; 4.000 A, 10.00 A
  • Accuracy:  +/- (1.0% rdg + 2 LSD)
  • DC Current:
  • Range: 400.0 Ω; 4.000 kΩ, 40.00 kΩ, 400.0 kΩ, 4.000 MΩ, 40.00 MΩ
  • Accuracy: +/- (1.0% rdg + 2 LSD) @ 4 kΩ to 400 kΩ ranges
  • Battery test: 0.1% to 99.9%  
  • Duty cycle:
  • Range: 1.5V, 9
  • Accuracy: +/- (1.0% rdg + 3 LSD)
  • Ambient temperature:
  • 23°C ±5°C (73.4°F ±9°F)
  • Relative temperature:  =75%
  • Accuracy: ±(% of reading + digits)
  • Maximum voltage between input terminal and earth ground: AC 600Vrms or DC 600V
  • Fuse for mA µA input: 0.5A H 600V fast-fuse, (Φ6×32)mm
  • Fuse for 10A input: 10A H 600V fast-fuse, (Φ6×32)mm
  • Maximum display: Digital 3999 counts, updates 3/sec. Frequency: 4999 counts
  • Over-range indication: OL
  • Range: Automatic
  • Altitude: Operating = 2000m
  • Operating temperature: 0°C ~ +40°C (32°F ~ 104°F)
  • Relative humidity 0°C: ~ +30°C (32°F ~ 86°F) =75%; +30°C ~ +40°C (86°F ~ 104°F) =50%
  • Storage temperature: -10°C ~ +50°C (14°F ~ 122°F)
  • Electromagnetic compatibility: In an RF filed of 1V/m = Speci?ed accuracy ±5%
  • Battery: 9V, 6F22, NEDA1604 or equivalent
  • Dimensions (L x W x H): 182 mm x 90 mm x 45 mm (7.2 in x 3.5 in x 1.8 in)
  • Weight: Approx. 354g (0.78lb) with batteries installed
DC Voltage Measurement
  • Input impedance: around 10MΩ; (Input impedance > 3GΩ for DC 400mV range)
  • Overload protection: ?600V
AC Voltage Measurement
  • Note: 400.0mV range is available for manual range only.
  • Input impedance: around 10MΩ
  • Frequency response: 45Hz ~ 400Hz
Average sensing, rms indication:
  • Overload protection: 600Vrms
Resistance Measurement
  • 400Ω range: Measured value = (Measured display value) ? (Short-circuiting value of probe)
  • Open circuit voltage: around 0.5V
  • Overload protection: 600Vrms
Continuity and Diode measurement
  • Overload protection: 600Vrms
Capacitance Measurement
  • Overload protection: 600Vrms
  • Measurement of frequency/duty cycle
  • Overload protection: 600Vrm
  • Input amplitude (DC level is 0.)
  • 10Hz~1MHz: 300mV ≤ a ≤30Vrms
  • >1MHz~10MHz: 600mV ≤ a ≤30Vrms
  • Input amplitude and frequency response must meet following conditions when reading frequency or duty cycle during AC voltage or current measurement
  • Input amplitude = Range × 30%
  • Frequency response: =400Hz
Battery Test:
  • Overload protection: F1 fuse, 0.5A H 600V fast-fuse, (Φ6x32)mm
  • For 1.5V range: Load resistance is around 30Ω.
  • For 9V range: Load resistance is around 1kΩ
DC Current Measurement
  • Overload protection: mA /μA input:F1 fuse, 0.5A H 600V fast-fuse, (Φ6x32)mm
  • 10 A input: F2 fuse, 10A H 600V fast-fuse, (Φ6x32)mm
AC Current Measurement
  • Frequency response: 45Hz ~ 400Hz Average sensing, rms indication
  • Overload protection: mA /μA input:F1 fuse, 0.5A H 600V fast-fuse, (Φ6x32)mm
  • 10 A input: F2 fuse, 10A H 600V fast-fuse, (Φ 6x32)mm

  • (1) AM-510 Multimeter
  • (1) 9V (6F22) Battery, Installed
  • (1) Test leads
  • (1) Users manual

Download

Note: Prices are not binding at any time subject to change without prior notice